9.3
CVE-2025-41769: Unauthenticated Buffer Overflow in PROFINET Service on Siemens SIMATIC Devices
CVE-2025-41769 · published 2 months ago
Summary
The PROFINET service on some Siemens SIMATIC devices has a security weakness that could allow an attacker to remotely reboot the device or run malicious code. This is particularly concerning for industrial control systems, where a device reboot could disrupt operations. To address this, device manufacturers and users should apply available security updates and follow secure configuration best practices.
What to do
- Update phoenix contact axc f 1152 to version 2026.0.3 or later.
- Update phoenix contact axc f 1252 to version 2026.0.3 or later.
- Update phoenix contact axc f 2152 to version 2026.0.3 or later.
- Update phoenix contact axc f 3152 to version 2026.0.3 or later.
- Update phoenix contact bpc 9102s to version 2026.0.3 or later.
- Update phoenix contact bpc 9202s to version 2026.0.3 or later.
- Update phoenix contact rfc 4072r to version 2026.0.3 or later.
- Update phoenix contact rfc 4072s to version 2026.0.3 or later.
- Update phoenix contact vl3 upc 2440 edge to version 2026.0.3 or later.
- Update phoenix contact vplcnext control 1000 to version 2026.0.3 or later.
- Update phoenix contact vplcnext control 2000 to version 2026.0.3 or later.
- Update phoenix contact vplcnext control 3000 to version 2026.0.3 or later.
- Update phoenix contact vplcnext control 500 to version 2026.0.3 or later.
- Update phoenix contact epc 1502 to version 2026.0.3 or later.
- Update phoenix contact epc 1522 to version 2026.0.3 or later.
Affected software
| Vendor | Product | Affected versions |
|---|---|---|
| phoenix contact | axc f 1152 | < 2026.0.3 |
| phoenix contact | axc f 1252 | < 2026.0.3 |
| phoenix contact | axc f 2152 | < 2026.0.3 |
| phoenix contact | axc f 3152 | < 2026.0.3 |
| phoenix contact | bpc 9102s | < 2026.0.3 |
| phoenix contact | bpc 9202s | < 2026.0.3 |
| phoenix contact | rfc 4072r | < 2026.0.3 |
| phoenix contact | rfc 4072s | < 2026.0.3 |
| phoenix contact | vl3 upc 2440 edge | < 2026.0.3 |
| phoenix contact | vplcnext control 1000 | < 2026.0.3 |
| phoenix contact | vplcnext control 2000 | < 2026.0.3 |
| phoenix contact | vplcnext control 3000 | < 2026.0.3 |
| phoenix contact | vplcnext control 500 | < 2026.0.3 |
| phoenix contact | epc 1502 | < 2026.0.3 |
| phoenix contact | epc 1522 | < 2026.0.3 |
Original advisory text
Unauthenticated Buffer Overflow in PROFINET Service
The device's PROFINET service is affected by a buffer overflow vulnerability that exists in the default configuration. An unauthenticated remote attacker could exploit this vulnerability to reboot the device or execute arbitrary code.
Internet-facing
3 days
Internal
60 days
- Not known to be exploited
- Can be exploited automatically
- Gives an attacker full control
Type
CWE-120Classic Buffer Overflow
Timeline
Published12 Aug 2026
Updated31 Oct 2026
First seen12 Aug 2026
Track software like this