Track vulnerabilities like this one. Sign up free to get alerted when software you use is affected.
7.2

CVE-2024-39351: A vulnerability regarding improper neutralization of special elements used in an OS command ('OS Command Injection') is found in the NTP configuration. This allows remote authenticated users with a...

CVE-2024-39351 · published 2 years ago
Summary

A vulnerability regarding improper neutralization of special elements used in an OS command ('OS Command Injection') is found in the NTP configuration. This allows remote authenticated users with administrator privileges to execute arbitrary commands via unspecified vectors. The following models wit...

What to do
  • Update synology bc500_firmware to version 1.0.7-0298 or later.
  • Update synology tc500_firmware to version 1.0.7-0298 or later.
Affected software
VendorProductAffected versions
synology bc500_firmware < 1.0.7-0298
cpe:2.3:o:synology:bc500_firmware:*:*:*:*:*:*:*:*
synology tc500_firmware < 1.0.7-0298
cpe:2.3:o:synology:tc500_firmware:*:*:*:*:*:*:*:*
Original advisory text
A vulnerability regarding improper neutralization of special elements used in an OS command ('OS Command Injection') is found in the NTP configuration. This allows remote authenticated users with a...
A vulnerability regarding improper neutralization of special elements used in an OS command ('OS Command Injection') is found in the NTP configuration. This allows remote authenticated users with administrator privileges to execute arbitrary commands via unspecified vectors. The following models with Synology Camera Firmware versions before 1.0.7-0298 may be affected: BC500 and TC500.
Fix within
Internet-facing 14 days
Internal At next upgrade
  • Not known to be exploited
  • Needs hands-on effort to exploit
  • Gives an attacker full control
Severity
7.2 High
Exploitation
2% chance of attack within 30 days
Type
CWE-78OS Command Injection
Timeline
Published28 Jun 2024
Updated3 Nov 2026
First seen29 Sep 2026
Sources
Track software like this
Free during beta