6.5

CVE-2019-6540: Medtronic monitors and devices send data unencrypted

CVE-2019-6540 · published 7 years ago
Summary

The telemetry connection used by Medtronic MyCareLink monitors and several related implanted devices does not encrypt the information it transmits. Someone standing close enough to the device could intercept and read that data, including personal health details. Apply any available firmware updates from Medtronic and keep the devices in physically secure locations to reduce the risk.

What to do

The CVE record does not list a fixed version. Check the vendor's site or the advisory links below - a fix may already be released.

Affected software
VendorProductAffected versions
medtronic mycarelink_monitor_24950_firmware All versions
cpe:2.3:o:medtronic:mycarelink_monitor_24950_firmware:-:*:*:*:*:*:*:*
medtronic mycarelink_monitor_24952_firmware All versions
cpe:2.3:o:medtronic:mycarelink_monitor_24952_firmware:-:*:*:*:*:*:*:*
medtronic carelink_monitor_2490c_firmware All versions
cpe:2.3:o:medtronic:carelink_monitor_2490c_firmware:-:*:*:*:*:*:*:*
medtronic carelink_2090_firmware All versions
cpe:2.3:o:medtronic:carelink_2090_firmware:-:*:*:*:*:*:*:*
medtronic amplia_crt-d_firmware All versions
cpe:2.3:o:medtronic:amplia_crt-d_firmware:-:*:*:*:*:*:*:*
medtronic claria_crt-d_firmware All versions
cpe:2.3:o:medtronic:claria_crt-d_firmware:-:*:*:*:*:*:*:*
medtronic compia_crt-d_firmware All versions
cpe:2.3:o:medtronic:compia_crt-d_firmware:-:*:*:*:*:*:*:*
medtronic concerto_crt-d_firmware All versions
cpe:2.3:o:medtronic:concerto_crt-d_firmware:-:*:*:*:*:*:*:*
medtronic concerto_ii_crt-d_firmware All versions
cpe:2.3:o:medtronic:concerto_ii_crt-d_firmware:-:*:*:*:*:*:*:*
medtronic consulta_crt-d_firmware All versions
cpe:2.3:o:medtronic:consulta_crt-d_firmware:-:*:*:*:*:*:*:*
medtronic evera_icd_firmware All versions
cpe:2.3:o:medtronic:evera_icd_firmware:-:*:*:*:*:*:*:*
medtronic maximo_ii_crt-d_firmware All versions
cpe:2.3:o:medtronic:maximo_ii_crt-d_firmware:-:*:*:*:*:*:*:*
medtronic maximo_ii_icd_firmware All versions
cpe:2.3:o:medtronic:maximo_ii_icd_firmware:-:*:*:*:*:*:*:*
medtronic mirro_icd_firmware All versions
cpe:2.3:o:medtronic:mirro_icd_firmware:-:*:*:*:*:*:*:*
medtronic nayamed_nd_icd_firmware All versions
cpe:2.3:o:medtronic:nayamed_nd_icd_firmware:-:*:*:*:*:*:*:*
medtronic primo_icd_firmware All versions
cpe:2.3:o:medtronic:primo_icd_firmware:-:*:*:*:*:*:*:*
medtronic protecta_icd_firmware All versions
cpe:2.3:o:medtronic:protecta_icd_firmware:-:*:*:*:*:*:*:*
medtronic protecta_crt-d_firmware All versions
cpe:2.3:o:medtronic:protecta_crt-d_firmware:-:*:*:*:*:*:*:*
medtronic secura_icd_firmware All versions
cpe:2.3:o:medtronic:secura_icd_firmware:-:*:*:*:*:*:*:*
medtronic virtuoso_icd_firmware All versions
cpe:2.3:o:medtronic:virtuoso_icd_firmware:-:*:*:*:*:*:*:*
medtronic virtuoso_ii_icd_firmware All versions
cpe:2.3:o:medtronic:virtuoso_ii_icd_firmware:-:*:*:*:*:*:*:*
medtronic visia_af_icd_firmware All versions
cpe:2.3:o:medtronic:visia_af_icd_firmware:-:*:*:*:*:*:*:*
medtronic viva_crt-d_firmware All versions
cpe:2.3:o:medtronic:viva_crt-d_firmware:-:*:*:*:*:*:*:*
Original advisory text
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CR...
The Conexus telemetry protocol utilized within Medtronic MyCareLink Monitor versions 24950 and 24952, CareLink Monitor version 2490C, CareLink 2090 Programmer, Amplia CRT-D, Claria CRT-D, Compia CRT-D, Concerto CRT-D, Concerto II CRT-D, Consulta CRT-D, Evera ICD, Maximo II CRT-D and ICD, Mirro ICD, Nayamed ND ICD, Primo ICD, Protecta ICD and CRT-D, Secura ICD, Virtuoso ICD, Virtuoso II ICD, Visia AF ICD, and Viva CRT-D does not implement encryption. An attacker with adjacent short-range access to a target product can listen to communications, including the transmission of sensitive data.
References
Fix within
Internet-facing 60 days
Internal At next upgrade
  • Not known to be exploited
  • Needs hands-on effort to exploit (estimated)
  • Gives an attacker partial control (estimated)
Severity
6.5 Medium
Exploitation
<1% chance of attack within 30 days
Type
CWE-319Cleartext Transmission of Sensitive Information
Timeline
Published26 Mar 2019
Updated4 Nov 2026
First seen29 Sep 2026
Sources