Track vulnerabilities like this one.
Sign up free to get alerted when software you use is affected.
8.1
CVE-2018-11458: SINUMERIK machines risk remote code execution via open VNC port
CVE-2018-11458 · published 7 years ago
Summary
The SINUMERIK 828D V4.7 and 840D sl V4.7/V4.8 controllers contain a built‑in VNC service that can be tricked into running malicious code if the VNC port (5900) is opened in the firewall. An attacker on the network could then take control of the machine without needing any credentials or user action. Close the VNC port in the firewall or apply the latest firmware updates that disable or secure this service.
What to do
The CVE record does not list a fixed version. Check the vendor's site or the advisory links below - a fix may already be released.
Affected software
| Vendor | Product | Affected versions |
|---|---|---|
| siemens | sinumerik_828d_v4.7_firmware |
<= 4.7 cpe:2.3:o:siemens:sinumerik_828d_v4.7_firmware:*:*:*:*:*:*:*:* |
| siemens | sinumerik_840d_sl_v4.7_firmware |
<= 4.7 cpe:2.3:o:siemens:sinumerik_840d_sl_v4.7_firmware:*:*:*:*:*:*:*:* |
| siemens | sinumerik_840d_sl_v4.8_firmware |
<= 4.8 cpe:2.3:o:siemens:sinumerik_840d_sl_v4.8_firmware:*:*:*:*:*:*:*:* |
Original advisory text
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The...
A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions < V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions < V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions < V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to execute code with privileged permissions on the system by sending specially crafted network requests to port 5900/tcp. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known.
References
- http://www.securityfocus.com/bid/106185 Third Party Advisory VDB Entry
- https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf Vendor Advisory
Internet-facing
3 days
Internal
60 days
- Not known to be exploited
- Can be exploited automatically (estimated)
- Gives an attacker full control (estimated)
Type
CWE-190Integer Overflow
Timeline
Published12 Dec 2018
Updated30 Oct 2026
First seen29 Sep 2026
Sources
CVE-2018-11458 · NVD